Temperature Converter
Convert any temperature between Celsius, Fahrenheit, Kelvin, Rankine, Réaumur, Rømer, Newton and Delisle with the formula and every step, convert temperature differences, print a °F to °C chart, convert oven temperatures and gas marks, and compare armpit, ear, oral and rectal readings, with a figure and four charts.
By StatsUnlock Team · Exact SI definitions (0 °C = 273.15 K), checked against ITS-90 and published thermometry reviews · Last updated:
⚡ 0. Quick Answer
A temperature converter uses °F = °C × 9/5 + 32, °C = (°F − 32) × 5/9 and K = °C + 273.15. So 37 °C = 37 × 1.8 + 32 = 98.6 °F = 310.15 K, and 300 K = 26.85 °C. A thermometer good to ±0.1 °C is good to ±0.18 °F.
Rule of thumb: double the Celsius and add 30 for a quick Fahrenheit estimate (20 °C ≈ 70 °F; exact 68 °F). For a temperature difference, leave out the 32: a 10 °C rise is an 18 °F rise.
⭐ Key Takeaways
- A temperature converter turns 37 °C into 98.6 °F (37 × 9/5 + 32) and 98.6 °F back into 37 °C ((98.6 − 32) × 5/9).
- Kelvin has no degree sign and no negatives: 573 K = 299.85 °C; 300 K = 26.85 °C; 0 K = −273.15 °C = −459.67 °F.
- Celsius and Fahrenheit agree at exactly −40.
- Oven: 350 °F ≈ 177 °C (gas mark 4, about 160 °C in a fan oven); 180 °C ≈ 356 °F.
- An armpit reading is usually 0.3 to 0.6 °C lower than by mouth, and a rectal or ear reading 0.3 to 0.6 °C higher.
📚 1. What Is a Temperature Converter?
Temperature scales differ in two ways: the size of one degree and where zero sits. A Celsius degree is 1.8 times a Fahrenheit degree, and 0 °C is 32 °F. Kelvin uses Celsius-sized degrees but starts at absolute zero, so K = °C + 273.15. Since 2019 the kelvin has been defined by fixing the Boltzmann constant (Stöck et al., 2019), and practical thermometers follow the International Temperature Scale of 1990 (Preston-Thomas, 1990). A temperature converter applies both the scale factor and the offset, exactly, in either direction.
A worked one-liner: °F = 37 × 9/5 + 32 = 66.6 + 32 = 98.6 °F; K = 37 + 273.15 = 310.15 K; °R (Rankine) = 310.15 × 1.8 = 558.27 °R.
Who uses it: students converting between Celsius, Fahrenheit and Kelvin in chemistry and physics; cooks converting oven temperatures and gas marks; parents and nurses reading thermometers; travelers checking the weather; engineers using Rankine; and lab staff converting thermometer tolerances. One page replaces separate °C to °F, °F to °C, Kelvin, oven and body-temperature converters.
Quick answers to the questions people ask most
How do you convert Celsius to Fahrenheit?
Multiply the Celsius temperature by 9/5 (1.8) and add 32. For 25 °C: 25 × 1.8 = 45, and 45 + 32 = 77 °F. For 37 °C: 37 × 1.8 = 66.6, plus 32 is 98.6 °F. A quick mental estimate is to double the Celsius value and add 30, which is close between 0 and 20 °C.
How do you convert Fahrenheit to Celsius?
Subtract 32 from the Fahrenheit temperature, then multiply by 5/9. For 98.6 °F: 98.6 − 32 = 66.6, and 66.6 × 5/9 = 37 °C. For 350 °F: 318 × 5/9 = 176.7 °C. Always subtract first, then multiply; doing it the other way round gives a wrong answer.
How do you convert Celsius to Kelvin?
Add 273.15 to the Celsius temperature. 25 °C is 298.15 K and 100 °C is 373.15 K. To go back, subtract 273.15: 300 K is 26.85 °C and 573 K is 299.85 °C. Kelvin is written without a degree sign, and it can never be negative because 0 K is absolute zero.
What is the formula to convert Fahrenheit to Kelvin?
Convert to Celsius first, then add 273.15: K = (°F − 32) × 5/9 + 273.15. For 68 °F: 36 × 5/9 = 20 °C, and 20 + 273.15 = 293.15 K. Or use Rankine: K = °R × 5/9, where °R = °F + 459.67, which gives the same 293.15 K.
At what temperature are Celsius and Fahrenheit equal?
At −40. Setting C = C × 9/5 + 32 and solving gives C = −40, so −40 °C is exactly −40 °F. Above that, the Fahrenheit number is always larger; below it, the Celsius number is larger. Chart 2 in the results shows the two lines crossing there.
How do you convert a temperature difference?
Multiply by the ratio of degree sizes and leave out the offset. A change of 10 °C is a change of 18 °F, not 50 °F, and a change of 10 K. The same applies to thermometer tolerances: ±0.5 °C is ±0.9 °F. Choose Difference in the calculator to convert rises, drops and ranges.
| Scale | Water freezes | Water boils (1 atm) | Absolute zero | From °C |
|---|---|---|---|---|
| Celsius (°C) | 0 | 100 | −273.15 | C |
| Fahrenheit (°F) | 32 | 212 | −459.67 | C × 9/5 + 32 |
| Kelvin (K) | 273.15 | 373.15 | 0 | C + 273.15 |
| Rankine (°R) | 491.67 | 671.67 | 0 | (C + 273.15) × 9/5 |
| Réaumur (°Ré) | 0 | 80 | −218.52 | C × 4/5 |
🧮 2. Enter Your Temperature
Up to 1000 rows. Download the chart as a PDF from the results, or copy it from Section 5.
General guide only, not medical advice. Offsets between sites are averages and vary between people and thermometers.
One temperature per line with its unit (C, F, K, R, Re, Ro, N, De), with an optional label after a comma. A header row is skipped.
📊 3. Results and Step-by-Step Working
Working (Given, Required, Equation, Substitute, Solve)
Uncertainty budget
Step by step
Full results table
Your temperature, drawn from the numbers
Charts
Four plots that change with the mode: the scales side by side, the conversion line, landmarks and degree sizes.
1.
2.
3.
4.
🧠 4. Understanding Your Temperature Conversion, In Detail
4.1 What the result means
___
4.2 The formula
___
4.3 Uncertainty and ranges
___
4.4 The detail that changes the answer
___
4.5 What to do next
___
4.6 Why 9/5 and 32?
Between the freezing and boiling points of water there are 100 Celsius degrees and 180 Fahrenheit degrees (32 to 212), so one Celsius degree equals 180 ÷ 100 = 1.8 = 9/5 Fahrenheit degrees. The scales also start at different places: 0 °C is 32 °F. Every conversion between two linear scales is therefore a multiply and an add. Kelvin keeps the Celsius degree size but moves zero to absolute zero, −273.15 °C, the point fixed exactly by the 2019 redefinition of the kelvin through the Boltzmann constant (Fischer et al., 2018; Machin, 2018).
4.7 Readings versus differences
A reading (it is 25 °C) needs the full formula with the offset. A difference (it warmed by 5 °C, the thermometer is accurate to ±0.2 °C, the oven runs 10 °C hot) needs only the factor: 5 °C = 9 °F = 5 K. Choosing the wrong one is the single most common temperature conversion error. In the calculator, set “This is a” to Difference for changes and ranges.
4.8 Kelvin in science
Gas laws, reaction rates and radiation all use absolute temperature. Doubling 10 °C to 20 °C does not double the thermal energy; going from 283.15 K to 293.15 K is a 3.5% increase. Always convert to kelvin before using PV = nRT, the Arrhenius equation or the Stefan-Boltzmann law, and write “K”, not “°K”. Modern thermometry and its traceability are reviewed by Moldover et al. (2016).
✍ 5. How to Write Temperatures in a Report: Detailed Results
A temperature in a report needs the number, the unit with its symbol (°C, °F, K), a space between them, and for measured values the uncertainty and, for body temperatures, the site. The seven write-ups below are filled from the temperature converter; they show the headline example until you press Convert.
Showing the headline example (37 °C to °F). Press Convert above to fill all seven write-ups with your own result.
5.1 Style rules
| Rule | Write | Avoid |
|---|---|---|
| Space between number and unit | 37 °C, 310.15 K | 37°C, 37 ° C |
| Kelvin has no degree sign | 300 K | 300 °K |
| Differences in K or °C | rose by 5 K (5 °C) | rose by 41 °F |
| Give both units for mixed audiences | 180 °C (356 °F) | 180 °C only, for US readers |
| Match decimals to the reading | 98.6 °F = 37.0 °C | 37.0000 °C |
| Name the body site | 38.2 °C (tympanic) | “temp 38.2” |
5.2 Seven ready-to-copy write-ups
∑ 6. What Is the Temperature Conversion Formula? All Formulas Used
🔀 7. How Do You Convert a Temperature? Flowchart, Step by Step
The same worked problem as Sections 0, 9, 10, 11 and 14: convert 37 °C (thermometer ±0.1 °C) to Fahrenheit and Kelvin.
📝 8. How to Use This Temperature Converter
- Pick what you want to do. Choose a mode in Section 2: convert a temperature, build a conversion chart, convert an oven temperature or gas mark, or compare body temperature sites.
- Load a sample or type your value. Twelve worked problems are in the sample menu. Sample 1 is the headline problem. Nothing is calculated until you press Convert.
- Choose the from and to scales. Celsius, Fahrenheit, Kelvin, Rankine, Réaumur, Rømer, Newton or Delisle. Use Swap to reverse them.
- Say whether it is a reading or a difference. A reading (it is 25 °C) uses the offset; a difference (it rose 5 °C, ± 0.2 °C) does not.
- Add the thermometer accuracy. Optional: the ± tolerance is converted by the degree size, so ± 0.1 °C becomes ± 0.18 °F.
- Set decimal places. Auto shows the exact result trimmed of binary noise, or choose 0 to 4 decimals.
- Press Convert Temperature. Press the button or Enter. The answer on every scale, a Verified badge, the formula and every step appear in Section 3.
- Read the figure and charts. The thermometer figure and four charts show the scales side by side, the conversion line, landmarks and degree sizes.
- Copy the write-up. Section 5 fills seven ready texts for a report, a log, code, an exam, chat, a results paragraph and a table.
- Print a chart or run a batch. Download Doc or PDF, build a printable table in chart mode, or convert a whole column in the Batch tab.
📈 9. How to Convert Temperature in Excel
Excel has a built-in CONVERT function for temperature, and the formulas are short enough to type by hand. The sheet repeats the headline problem (37 °C ± 0.1 °C), so the numbers match Sections 0, 7, 10, 11 and 14.
=CONVERT(A2,"C","F"). It returns 98.6.9.1 The formulas you need
| You want | Excel formula | Note |
|---|---|---|
| °C to °F | =A2*9/5+32 or =CONVERT(A2,"C","F") | 37 → 98.6 |
| °F to °C | =(A2-32)*5/9 or =CONVERT(A2,"F","C") | 98.6 → 37 |
| °C to K | =A2+273.15 or =CONVERT(A2,"C","K") | Unit code "K" |
| K to °C | =A2-273.15 | 300 → 26.85 |
| °F to K | =CONVERT(A2,"F","K") | 68 → 293.15 |
| °C to Rankine | =CONVERT(A2,"C","Rank") | Unit code "Rank" |
| °C to Réaumur | =CONVERT(A2,"C","Reau") | Unit code "Reau" |
| A difference or tolerance in °F | =A2*9/5 | No + 32 |
| Round for display | =ROUND(A2*9/5+32,1) | One decimal |
9.2 Step by step
1 Enter the temperature
Celsius in A2. Numbers only.
A2 holds 37.
2 Fahrenheit
In B2 type =A2*9/5+32.
B2 shows 98.6.
3 Kelvin and Rankine
In C2 type =A2+273.15; in D2 type =C2*9/5.
C2 shows 310.15; D2 shows 558.27.
4 Convert the tolerance
In E2 put 0.1; in F2 type =E2*9/5 (no + 32).
F2 shows 0.18: 98.6 ± 0.18 °F.
9.3 A printable chart
Put 0 in A2 and =A2+10 in A3, fill down to 220. In B2 type =ROUND((A2-32)*5/9,1) and fill down. Print the two columns as a °F to °C chart.
9.4 Why Excel may differ from R or Python
| Situation | What happens | Fix |
|---|---|---|
| Binary rounding | Python may print 37.00000000000001 | Round to 10 decimals or format the output |
| ROUND | Excel rounds half away from zero; Python round() rounds half to even | Round only the final value |
| Unit codes | CONVERT needs "C", "F", "K", "Rank", "Reau" exactly | Check the case |
9.5 Charting
Select the °C and °F columns and insert a Scatter chart with straight lines. The line has slope 1.8 and crosses the line °F = °C at −40.
9.6 Errors you may see
#N/A: a CONVERT unit code in the wrong case, such as "c".#VALUE!: a degree sign typed into a number cell ("37 °C").- A temperature that looks 32 too high: + 32 was added to a difference.
📈 10. How to Convert Temperature in R
A complete, copy-and-run script that reproduces the temperature converter for the headline problem. It converts 37 °C to every main scale, converts the thermometer tolerance and a temperature difference correctly (without the offset), prints a °F to °C chart and saves one 300 dpi figure.
10.1 The complete script
R, base only, saves celsius_fahrenheit.png
# Temperature conversion: all scales, a tolerance, a difference and a printable chart
# StatsUnlock - https://statsunlock.com/temperature-converter/ Base R only.
to_c <- list(C = function(x) x, F = function(x) (x - 32) * 5 / 9, K = function(x) x - 273.15, R = function(x) x * 5 / 9 - 273.15)
from_c <- list(C = function(c) c, F = function(c) c * 9 / 5 + 32, K = function(c) c + 273.15, R = function(c) (c + 273.15) * 9 / 5)
convert <- function(x, from, to) {
c <- to_c[[from]](x)
if (any(c < -273.15)) stop("below absolute zero")
round(from_c[[to]](c), 10) # round away binary noise
}
# ---- 1. Headline: 37 C with a +/-0.1 C thermometer ----
t <- 37; tol <- 0.1
cat(sprintf("%g C = %g F = %g K = %g R\n", t, convert(t, "C", "F"), convert(t, "C", "K"), convert(t, "C", "R")))
cat(sprintf("Tolerance +/-%g C = +/-%.2f F (a difference: no + 32)\n", tol, tol * 9 / 5))
cat(sprintf("98.6 F = %g C; 300 K = %g C; 573 K = %g C\n", convert(98.6, "F", "C"), convert(300, "K", "C"), convert(573, "K", "C")))
stopifnot(convert(convert(t, "C", "F"), "F", "C") == t)
# ---- 2. Difference and crossover ----
cat(sprintf("A 10 C rise = %g F rise = 10 K rise\n", 10 * 9 / 5))
cat("C equals F at -40 ->", convert(-40, "C", "F"), "\n")
# ---- 3. Printable F to C chart ----
f <- seq(0, 220, by = 20)
print(data.frame(F = f, C = round(convert(f, "F", "C"), 2)), row.names = FALSE)
# ---- 4. One 300 dpi figure ----
cc <- seq(-60, 120, by = 1)
png("celsius_fahrenheit.png", width = 6, height = 4, units = "in", res = 300)
plot(cc, cc * 9 / 5 + 32, type = "l", lwd = 2.5, col = "#2563eb", xlab = "Celsius", ylab = "Fahrenheit")
abline(0, 1, lty = 2, col = "#94a3b8"); points(c(-40, 37), c(-40, 98.6), pch = 19, col = c("#9333ea", "#ea580c"))
invisible(dev.off())
10.2 Output
37 C = 98.6 F = 310.15 K = 558.27 R
Tolerance +/-0.1 C = +/-0.18 F (a difference: no + 32)
98.6 F = 37 C; 300 K = 26.85 C; 573 K = 299.85 C
A 10 C rise = 18 F rise = 10 K rise
C equals F at -40 -> -40
F C
0 -17.78
20 -6.67
40 4.44
60 15.56
80 26.67
100 37.78
120 48.89
140 60.00
160 71.11
180 82.22
200 93.33
220 104.4410.3 Traps
- The functions are vectorized: convert a whole column with one call.
round()rounds half to even; format withsprintffor fixed decimals.- Never add 32 to a difference or a tolerance.
10.4 What each part does
| Block | Purpose |
|---|---|
| to_c / from_c | Exact definitions, every scale routed through Celsius |
| convert() | Two steps with a check for absolute zero; rounding removes binary noise such as 37.00000000000001 |
| Tolerance | A ± range converts by 9/5 only, never with + 32 |
| Middle blocks | A 10 °C rise in °F, the −40 crossover and a 0 to 220 °F chart as a data frame |
| Last block | °F against °C with the −40 crossover and 37 °C marked, saved at 300 dpi |
10.5 Adapting it
Change t for your temperature and the from and to codes (C, F, K, R). Pass a whole vector or list to convert a column of readings at once.
📈 11. How to Convert Temperature in Python
A complete, copy-and-run script that reproduces the temperature converter for the headline problem. It converts 37 °C to every main scale, converts the thermometer tolerance and a temperature difference correctly (without the offset), prints a °F to °C chart and saves one 300 dpi figure.
Install once: pip install numpy matplotlib
11.1 The complete script
Python with NumPy and Matplotlib, saves celsius_fahrenheit.png
# Temperature conversion: all scales, a tolerance, a difference, a printable chart and one figure
# StatsUnlock - https://statsunlock.com/temperature-converter/
import numpy as np
import matplotlib
matplotlib.use("Agg")
import matplotlib.pyplot as plt
# ---- 1. Exact definitions (via Celsius) ----
to_c = {"C": lambda x: x, "F": lambda x: (x - 32) * 5 / 9, "K": lambda x: x - 273.15, "R": lambda x: x * 5 / 9 - 273.15}
from_c = {"C": lambda c: c, "F": lambda c: c * 9 / 5 + 32, "K": lambda c: c + 273.15, "R": lambda c: (c + 273.15) * 9 / 5}
def convert(x, frm, to):
c = to_c[frm](x)
if c < -273.15:
raise ValueError("below absolute zero")
return round(from_c[to](c), 10) # round away binary noise
# ---- 2. The headline: 37 C with a +/-0.1 C thermometer ----
t, tol = 37.0, 0.1
print(f"{t} C = {convert(t, 'C', 'F')} F = {convert(t, 'C', 'K')} K = {convert(t, 'C', 'R')} R")
print(f"Tolerance +/-{tol} C = +/-{tol * 9 / 5:.2f} F (a difference: no + 32)")
print(f"98.6 F = {convert(98.6, 'F', 'C')} C; 300 K = {convert(300, 'K', 'C')} C; 573 K = {convert(573, 'K', 'C')} C")
assert convert(convert(t, "C", "F"), "F", "C") == t
# ---- 3. A temperature difference ----
rise_c = 10
print(f"A {rise_c} C rise = {rise_c * 9 / 5:g} F rise = {rise_c} K rise")
# ---- 4. Crossover and a printable F to C chart ----
print("C equals F at", -40.0, "->", convert(-40, "C", "F"))
for f in range(0, 221, 20):
print(f"{f:>4} F = {convert(f, 'F', 'C'):7.2f} C")
# ---- 5. One 300 dpi figure ----
c = np.linspace(-60, 120, 181)
fig, ax = plt.subplots(figsize=(6, 4))
ax.plot(c, c * 9 / 5 + 32, color="#2563eb", lw=2.5, label="F = C x 9/5 + 32")
ax.plot(c, c, color="#94a3b8", lw=1, ls="--", label="F = C")
ax.plot(-40, -40, "o", color="#9333ea", ms=9, label="crossover -40")
ax.plot(37, 98.6, "o", color="#ea580c", ms=9, label="37 C = 98.6 F")
ax.set_xlabel("Celsius"); ax.set_ylabel("Fahrenheit"); ax.legend(frameon=False)
fig.tight_layout(); fig.savefig("celsius_fahrenheit.png", dpi=300)
11.2 Output
37.0 C = 98.6 F = 310.15 K = 558.27 R
Tolerance +/-0.1 C = +/-0.18 F (a difference: no + 32)
98.6 F = 37.0 C; 300 K = 26.85 C; 573 K = 299.85 C
A 10 C rise = 18 F rise = 10 K rise
C equals F at -40.0 -> -40.0
0 F = -17.78 C
20 F = -6.67 C
40 F = 4.44 C
60 F = 15.56 C
80 F = 26.67 C
100 F = 37.78 C
120 F = 48.89 C
140 F = 60.00 C
160 F = 71.11 C
180 F = 82.22 C
200 F = 93.33 C
220 F = 104.44 C11.3 Traps
- (98.6 - 32) * 5 / 9 gives 37.0 here, but other values can print with trailing binary digits; round(x, 10) removes them.
- Integer division: use / not //.
- Check for values below absolute zero before converting.
11.4 What each part does
| Block | Purpose |
|---|---|
| to_c / from_c | Exact definitions, every scale routed through Celsius |
| convert() | Two steps with a check for absolute zero; rounding removes binary noise such as 37.00000000000001 |
| Tolerance | A ± range converts by 9/5 only, never with + 32 |
| Middle blocks | A 10 °C rise in °F, the −40 crossover and a printed 0 to 220 °F chart |
| Last block | °F against °C with the −40 crossover and 37 °C marked, saved at 300 dpi |
11.5 Adapting it
Change t for your temperature and the from and to codes (C, F, K, R). Pass a whole vector or list to convert a column of readings at once.
📋 12. Temperature Conversion Charts: °C, °F, K, Oven and Body
12.1 Celsius to Fahrenheit chart
| °C | °F | K | °C | °F | K |
|---|---|---|---|---|---|
| -40 | −40.0 | 233.15 | 45 | 113.0 | 318.15 |
| -35 | −31.0 | 238.15 | 50 | 122.0 | 323.15 |
| -30 | −22.0 | 243.15 | 55 | 131.0 | 328.15 |
| -25 | −13.0 | 248.15 | 60 | 140.0 | 333.15 |
| -20 | −4.0 | 253.15 | 65 | 149.0 | 338.15 |
| -15 | 5.0 | 258.15 | 70 | 158.0 | 343.15 |
| -10 | 14.0 | 263.15 | 75 | 167.0 | 348.15 |
| -5 | 23.0 | 268.15 | 80 | 176.0 | 353.15 |
| 0 | 32.0 | 273.15 | 85 | 185.0 | 358.15 |
| 5 | 41.0 | 278.15 | 90 | 194.0 | 363.15 |
| 10 | 50.0 | 283.15 | 95 | 203.0 | 368.15 |
| 15 | 59.0 | 288.15 | 100 | 212.0 | 373.15 |
| 20 | 68.0 | 293.15 | 105 | 221.0 | 378.15 |
| 25 | 77.0 | 298.15 | 110 | 230.0 | 383.15 |
| 30 | 86.0 | 303.15 | 115 | 239.0 | 388.15 |
| 35 | 95.0 | 308.15 | 120 | 248.0 | 393.15 |
| 40 | 104.0 | 313.15 | 125 | 257.0 | 398.15 |
°F = °C × 9/5 + 32; K = °C + 273.15. Exact. Last checked: October 2026.
12.2 Fahrenheit to Celsius chart
| °F | °C | °F | °C | °F | °C |
|---|---|---|---|---|---|
| -40 | −40.0 | 70 | 21.1 | 180 | 82.2 |
| -30 | −34.4 | 80 | 26.7 | 190 | 87.8 |
| -20 | −28.9 | 90 | 32.2 | 200 | 93.3 |
| -10 | −23.3 | 100 | 37.8 | 210 | 98.9 |
| 0 | −17.8 | 110 | 43.3 | 220 | 104.4 |
| 10 | −12.2 | 120 | 48.9 | 230 | 110.0 |
| 20 | −6.7 | 130 | 54.4 | 240 | 115.6 |
| 30 | −1.1 | 140 | 60.0 | 250 | 121.1 |
| 40 | 4.4 | 150 | 65.6 | 260 | 126.7 |
| 50 | 10.0 | 160 | 71.1 | 270 | 132.2 |
| 60 | 15.6 | 170 | 76.7 | 280 | 137.8 |
°C = (°F − 32) × 5/9, rounded to 0.1 °C. Last checked: October 2026.
12.3 Landmark and ITS-90 fixed-point temperatures
| Point | °C | °F | K | Note |
|---|---|---|---|---|
| Absolute zero | −273.15 | −459.67 | 0 | definition |
| Liquid nitrogen boils | −195.79 | −320.42 | 77.36 | 1 atm |
| Dry ice sublimes | −78.5 | −109.3 | 194.65 | 1 atm |
| Celsius equals Fahrenheit | −40 | −40 | 233.15 | exact |
| Mercury freezes | −38.83 | −37.9 | 234.32 | ITS-90 fixed point |
| Water freezes | 0 | 32 | 273.15 | 1 atm |
| Triple point of water | 0.01 | 32.02 | 273.16 | ITS-90 fixed point |
| Room temperature (lab) | 20 | 68 | 293.15 | glassware calibration |
| Standard ambient | 25 | 77 | 298.15 | chemistry |
| Gallium melts | 29.76 | 85.58 | 302.91 | ITS-90 fixed point |
| Average body (oral) | 36.6 | 97.88 | 309.75 | modern average |
| Wunderlich’s normal | 37 | 98.6 | 310.15 | historical |
| Water boils | 99.97 | 211.95 | 373.12 | 1 atm (ITS-90) |
| Indium freezes | 156.6 | 313.88 | 429.75 | ITS-90 fixed point |
| Moderate oven | 180 | 356 | 453.15 | gas mark 4 |
| Tin freezes | 231.93 | 449.47 | 505.08 | ITS-90 fixed point |
| Zinc freezes | 419.53 | 787.15 | 692.68 | ITS-90 fixed point |
| Aluminum freezes | 660.32 | 1220.58 | 933.47 | ITS-90 fixed point |
| Silver freezes | 961.78 | 1763.2 | 1234.93 | ITS-90 fixed point |
| Gold freezes | 1064.18 | 1947.52 | 1337.33 | ITS-90 fixed point |
| Copper freezes | 1084.62 | 1984.32 | 1357.77 | ITS-90 fixed point |
Fixed points from the International Temperature Scale of 1990 (Preston-Thomas, 1990); on ITS-90 water boils at about 99.97 °C at 1 atm. Last checked: October 2026.
12.4 Oven temperatures and gas marks
| Gas mark | °C (conventional) | °C (fan) | °F | Description |
|---|---|---|---|---|
| ¼ | 110 | 90 | 225 | very cool |
| ½ | 120 | 100 | 250 | very cool |
| 1 | 140 | 120 | 275 | cool |
| 2 | 150 | 130 | 300 | cool |
| 3 | 170 | 150 | 325 | moderately cool |
| 4 | 180 | 160 | 350 | moderate |
| 5 | 190 | 170 | 375 | moderately hot |
| 6 | 200 | 180 | 400 | hot |
| 7 | 220 | 200 | 425 | hot |
| 8 | 230 | 210 | 450 | very hot |
| 9 | 240 | 220 | 475 | very hot |
| 10 | 260 | 240 | 500 | extremely hot |
UK gas mark table as printed on cookers and in recipe books; fan ovens about 20 °C lower. Check your oven with a thermometer. Last checked: October 2026.
12.5 Body temperature by site
| Site | Adult normal range (°C) | Normal range (°F) | Compared with oral | Usual fever threshold |
|---|---|---|---|---|
| Oral (mouth) | 33.2 to 38.2 | 91.8 to 100.8 | reference | 37.8 °C (100.0 °F) |
| Rectal | 34.4 to 37.8 | 93.9 to 100.0 | 0.3 to 0.6 °C higher | 38.0 °C (100.4 °F) |
| Ear (tympanic) | 35.4 to 37.8 | 95.7 to 100.0 | 0.3 to 0.6 °C higher | 38.0 °C (100.4 °F) |
| Armpit (axillary) | 35.5 to 37.0 | 95.9 to 98.6 | 0.3 to 0.6 °C lower | 37.2 °C (99.0 °F) |
| Forehead (temporal) | varies by device | varies by device | 0.3 to 0.6 °C lower | 37.5 °C (99.5 °F) |
Ranges from the systematic review of Sund-Levander et al. (2002); site differences from Niven et al. (2015) and Craig et al. (2002). General guidance, not medical advice. Last checked: October 2026.
12.6 The same temperature on eight scales
| Point | °C | °F | K | °R | °Ré | °Rø | °N | °De |
|---|---|---|---|---|---|---|---|---|
| Absolute zero | −273.15 | −459.67 | 0 | 0 | −218.52 | −135.9 | −90.14 | 559.73 |
| Water freezes | 0 | 32 | 273.15 | 491.67 | 0 | 7.5 | 0 | 150 |
| Body (37 °C) | 37 | 98.6 | 310.15 | 558.27 | 29.6 | 26.93 | 12.21 | 94.5 |
| Water boils | 100 | 212 | 373.15 | 671.67 | 80 | 60 | 33 | 0 |
Historical scales by their modern definitions against Celsius. Last checked: October 2026.
📈 13. Temperature Conversion Examples: Worked Problems
Eight worked problems that cover what a temperature converter meets: a textbook kelvin question, weather, a gas law, a recipe, a home thermometer, a climate difference, the crossover and an impossible value. Each number was checked in Python.
Convert 300 K and 573 K to the Celsius scale
Subtract 273.15.
Convert the following temperatures to the Celsius scale: 300 K and 573 K.
| Quantity | Value | Note |
|---|---|---|
| 300 K | 26.85 °C | 300 − 273.15 |
| 573 K | 299.85 °C | 573 − 273.15 |
| With 273 | 27 °C and 300 °C | textbook rounding |
What it means: Only the zero point differs.
How to write it: "300 K = 26.85 °C and 573 K = 299.85 °C."
72 °F in Celsius
Subtract 32, then × 5/9.
A US forecast says 72 °F. What is that in Celsius?
| Quantity | Value | Note |
|---|---|---|
| Exact | 22.2 °C | (72 − 32) × 5/9 |
| Quick estimate | 21 °C | (72 − 30) ÷ 2 |
| Feels | mild, comfortable |
What it means: Use the exact formula for anything that matters.
How to write it: "72 °F (22.2 °C)."
Gas law at 25 °C
Always kelvin.
A gas at 25 °C is heated to 50 °C at constant pressure. By what factor does its volume change?
| Quantity | Value | Note |
|---|---|---|
| T₁ | 298.15 K | 25 + 273.15 |
| T₂ | 323.15 K | 50 + 273.15 |
| V₂ ÷ V₁ | 1.084 | Charles’s law: V ∝ T |
What it means: Ratios of temperatures only make sense on an absolute scale.
How to write it: "Heating from 298.15 K to 323.15 K increases the volume by 8.4%."
350 °F, gas mark and fan oven
Three numbers for one setting.
A US recipe says bake at 350 °F. The cook has a UK fan oven.
| Quantity | Value | Note |
|---|---|---|
| Conventional | 176.7 °C (180 °C) | (350 − 32) × 5/9 |
| Gas mark | 4 | UK table |
| Fan oven | about 160 °C | 20 °C lower |
What it means: Recipes round to the nearest 5 or 10 degrees.
How to write it: "Bake at 180 °C (350 °F, gas mark 4; fan 160 °C)."
An armpit reading of 37.4 °C
Site matters.
A parent reads 37.4 °C under a child’s arm.
| Quantity | Value | Note |
|---|---|---|
| In °F | 99.3 °F | 37.4 × 9/5 + 32 |
| Oral equivalent | about 37.7 to 38.0 °C | armpit reads lower |
| Armpit fever threshold | 37.2 °C (99 °F) | general guidance |
What it means: A raised armpit reading may mean fever; confirm and contact a clinician if worried. Not medical advice.
How to write it: "Temperature 37.4 °C (99.3 °F), axillary."
1.5 °C of warming in Fahrenheit
A difference: no + 32.
A climate target limits warming to 1.5 °C above pre-industrial levels. What is that in °F?
| Quantity | Value | Note |
|---|---|---|
| Right | 2.7 °F | 1.5 × 1.8 |
| Wrong | 34.7 °F | added 32 to a difference |
| In kelvin | 1.5 K | same as °C |
What it means: Changes, ranges and tolerances convert by the factor only.
How to write it: "Warming of 1.5 °C (2.7 °F)."
When °C and °F agree
Solve C = 1.8C + 32.
At what temperature do Celsius and Fahrenheit thermometers show the same number?
| Quantity | Value | Note |
|---|---|---|
| Equation | C = 1.8C + 32 | |
| Solution | −40 | 32 ÷ (−0.8) |
| Check | −40 × 1.8 + 32 = −40 |
What it means: A handy check: any formula you write must give −40 for −40.
How to write it: "−40 °C = −40 °F."
−300 °C
Below absolute zero.
A student writes −300 °C in a gas-law answer.
| Quantity | Value | Note |
|---|---|---|
| In kelvin | −26.85 K | −300 + 273.15 |
| Absolute zero | 0 K = −273.15 °C | lowest possible |
| Verdict | Impossible | the converter refuses it |
What it means: A negative kelvin or below −273.15 °C means a sign or unit error.
How to write it: "Temperatures below −273.15 °C (0 K) are not physically possible."
✏️ 14. How Do You Convert Temperatures by Hand and Check a Thermometer? Steps
The written method, calculator keys and a short ice-point check, for the headline problem: 37 °C to °F and K, with a thermometer accurate to ± 0.1 °C.
14.1 The written method
- Reading or difference? 37 °C is a reading.
- Multiply by 9/5. 37 × 1.8 = 66.6.
- Add 32. 66.6 + 32 = 98.6 °F.
- Kelvin. 37 + 273.15 = 310.15 K.
- Tolerance. ± 0.1 × 1.8 = ± 0.18 °F (no + 32).
- Check. (98.6 − 32) × 5/9 = 37 ✓
14.2 On a calculator
| Step | Keys | Display |
|---|---|---|
| °C to °F | 37×9÷5+32= | 98.6 |
| °F to °C | (98.6−32)×5÷9= | 37 |
| K to °C | 573−273.15= | 299.85 |
| Casio fx-991EX built-in | SHIFT8 (CONV) → 38 (°C▸°F) | 98.6 |
14.3 Lab SOP: ice-point check of a thermometer
Purpose
Check a liquid-in-glass or digital thermometer at 0 °C and record its correction in °C and °F.
Equipment
Insulated beaker or vacuum flask; crushed ice from distilled water; distilled water; the thermometer under test; a stirring rod.
Hazards and controls
Low hazard. Handle glass thermometers carefully; if a mercury thermometer breaks, follow your site’s spill procedure. Wear safety goggles.
Procedure
- Fill the container with crushed ice and add distilled water to make a slush with no floating ice.
- Insert the thermometer to its immersion mark, away from the walls.
- Stir gently and wait 3 minutes for a steady reading.
- Read at eye level (glass) or record the display; take three readings a minute apart.
- Correction = 0.00 °C − mean reading.
Record sheet
| Item | Value | Unit |
|---|---|---|
| Readings | 0.3, 0.4, 0.4 | °C |
| Mean | 0.37 | °C |
| Correction | −0.37 (−0.66 °F) | °C |
Acceptance criteria
Correction within the thermometer’s stated accuracy (for example ± 0.5 °C). These are teaching-lab criteria; follow your SOP where they differ.
Sources of error and their direction
- Too much water, ice floating: reading high.
- Tap-water ice (impurities): reading slightly low.
- Not immersed enough: reading high (room heat).
- Parallax on a glass scale: either way.
14.4 Practice problems
1. Convert 20 °C to °F.
20 × 9/5 + 32 = 68 °F
2. Convert 212 °F to °C.
(212 − 32) × 5/9 = 100 °C
3. Convert 0 °F to °C.
(0 − 32) × 5/9 = −17.8 °C
4. Convert 25 °C to K.
298.15 K
5. Convert 77 K (liquid nitrogen) to °C.
77 − 273.15 = −196.15 °C
6. Convert 451 °F to °C.
232.8 °C
7. A thermometer is accurate to ± 0.3 °C. In °F?
± 0.54 °F
8. Convert 100 °F to K.
310.93 K
9. A pool warms by 4 °F. In °C?
4 × 5/9 = 2.2 °C
10. Convert −10 °C to °F.
14 °F
14.5 Mistakes that lose marks
- Multiplying by 5/9 before subtracting 32.
- Adding 32 to a difference or tolerance.
- Writing °K.
- Using 273 instead of 273.15 when the answer needs it.
- Using °C in a gas law.
- Leaving out the unit.
14.6 Check-yourself and lab questions
Check: Why subtract 32 before multiplying by 5/9?
The 32 is the offset between the zeros; it must be removed before the degree size is changed.
Check: Why does K never go negative?
Zero kelvin is absolute zero, the lowest possible temperature.
Check: What is a 20 °C difference in K?
20 K: kelvin and Celsius degrees are the same size.
Check: Which scale do gas laws need?
Kelvin (or Rankine): an absolute scale.
Lab: An ice-point check reads 0.4 °C. What correction applies near 0 °C?
Subtract 0.4 °C from readings near 0 °C.
Lab: Why is crushed ice with water used for the check?
A slush of pure ice and water sits at 0 °C at 1 atm.
Lab: Why is the boiling point not 100 °C on a mountain?
Lower air pressure lowers the boiling point.
Lab: Convert the ice-point correction to °F.
0.4 × 1.8 = 0.72 °F: a difference, no + 32.
✅ 15. Which Temperature Scale Should You Use?
| Situation | Use | Converter mode | Example |
|---|---|---|---|
| Science, lab, most countries | °C | Convert | 25 °C room temperature |
| US weather, cooking, medicine | °F | Convert | 72 °F = 22.2 °C |
| Gas laws, physics, chemistry calculations | K | Convert | 300 K = 26.85 °C |
| US engineering thermodynamics | °R | Convert | 32 °F = 491.67 °R |
| A printable reference | Chart | Conversion chart | °F to °C, 0 to 220 |
| A recipe from another country | °C, °F or gas mark | Oven | 350 °F = gas mark 4 |
| A thermometer reading at home | °C or °F with the site | Body | Armpit 37.4 °C |
- Temperatures are multiplied or divided (gas laws, ratios).
- You need an absolute scale with no negatives.
- Reporting to SI standards.
- Converting a rise, drop or ± tolerance.
- Comparing two readings.
- Converting a thermometer’s accuracy.
🔧 16. Common Temperature Conversion Mistakes
The arithmetic is simple, so almost every error is about order, offsets or measurement site. The temperature converter guards against each one below.
| Symptom | Cause | Fix |
|---|---|---|
| 98.6 °F gives 22.8 °C | Multiplied by 5/9 before subtracting 32 | Subtract 32 first: (98.6 − 32) × 5/9 |
| A 10 °C rise becomes 50 °F | Added 32 to a difference | Differences: × 1.8 only |
| Negative kelvin | Below absolute zero, or subtracted instead of added | K = °C + 273.15; never below 0 |
| Answer off by 0.15 | Used 273 instead of 273.15 | Use 273.15 for exact work |
| Gas law answer wrong | Used °C in PV = nRT | Convert to kelvin first |
| Cake burned in a fan oven | Used the conventional temperature | Lower by about 20 °C |
| Child’s armpit reading looks normal but feels hot | Axillary reads lower than core | Use the site equivalents (Sund-Levander et al., 2002) |
| Forehead and ear readings disagree | Peripheral thermometers vary by up to 1 °C | Confirm with an oral or rectal reading (Mogensen et al., 2018) |
| Written °K | Old notation | Kelvin has no degree sign: K |
| Spreadsheet gives #N/A | CONVERT unit codes are case sensitive | Use "C", "F", "K" exactly |
⚠️ 17. Assumptions and Limitations
| Assumption | How to check | If it fails |
|---|---|---|
| Scale definitions are exact | SI 2019: 0 °C = 273.15 K; °F = 1.8 °C + 32 | None: the unit conversion itself has no uncertainty |
| The reading is accurate | Calibrated thermometer | Enter the tolerance to carry it through |
| Water boils at 100 °C | Only at 1 standard atmosphere | Lower at altitude (about 95 °C at 1600 m) |
| Body site offsets are average | Individual and device differences | Differences of 0.5 °C or more are common (Niven et al., 2015) |
| Fan ovens run about 20 °C hotter | Oven thermometer | Some fans are 10 to 30 °C different |
| Gas marks follow the UK table | Cooker manual | Older or other-country cookers vary |
| Historical scales use modern definitions | Defined against Celsius | Original instruments differed |
The body temperature mode is a unit and site converter, not a diagnostic tool. Normal body temperature varies with age, sex, time of day and the person (Obermeyer et al., 2017; Geneva et al., 2019).
🎯 18. Conclusion
Your result
The temperature converter gives 37 °C = 98.6 °F. Use °F = °C × 9/5 + 32 and K = °C + 273.15, and convert differences without the offset.
What the temperature converter does
Temperature conversion is two numbers, a factor and an offset, but the mistakes happen in the order of operations, in differences, in kelvin and in where a body temperature was taken. This temperature converter covers eight scales, readings and differences, printable charts, oven settings and body-temperature sites, and shows every step.
Watch out for
- Subtract 32 before multiplying by 5/9.
- No offset for differences and tolerances.
- Kelvin for gas laws, with no degree sign.
- Fan ovens about 20 °C lower.
- Always note the body site.
Next steps
For repeated readings, use the mean calculator and standard deviation calculator. For density at a given temperature, the specific gravity calculator uses water density from 0 to 40 °C. Whatever the scale, start and finish with the temperature converter.
❓ 19. Frequently Asked Questions
Q1. How do you convert Celsius to Fahrenheit?
Multiply the Celsius temperature by 9/5, which is 1.8, then add 32. For 25 °C: 25 × 1.8 = 45, and 45 + 32 = 77 °F. For 37 °C: 37 × 1.8 = 66.6, plus 32 gives 98.6 °F. A quick estimate is to double the Celsius value and add 30, which is close between 0 and 20 °C.
Q2. How do you convert Fahrenheit to Celsius?
Subtract 32 from the Fahrenheit temperature, then multiply the result by 5/9. For 98.6 °F: 98.6 − 32 = 66.6, and 66.6 × 5/9 = 37 °C. For 72 °F: 40 × 5/9 = 22.2 °C. Always subtract 32 before multiplying; multiplying first gives a wrong answer. A quick check: 50 °F is exactly 10 °C.
Q3. What is the formula to convert temperature from Celsius to Fahrenheit?
The formula is °F = °C × 9/5 + 32. The 9/5 converts the size of the degree, because 100 Celsius degrees span 180 Fahrenheit degrees, and the 32 shifts the zero, because water freezes at 0 °C and 32 °F. The same formula written with decimals is °F = 1.8 × °C + 32.
Q4. What is the formula to convert temperature from Fahrenheit to Celsius?
The formula is °C = (°F − 32) × 5/9, or (°F − 32) ÷ 1.8. Subtract 32 to remove the offset between the two zero points, then multiply by 5/9 to change the degree size. For 212 °F, (212 − 32) × 5/9 = 100 °C, the boiling point of water at sea level.
Q5. How do you convert Celsius to Kelvin?
Add 273.15 to the temperature in degrees Celsius. 0 °C is 273.15 K, 25 °C is 298.15 K, and 100 °C is 373.15 K. Kelvin uses the same size of degree as Celsius but starts at absolute zero, so it is never negative, and it is written without a degree sign: 298.15 K, not 298.15 °K.
Q6. How do you convert 300 K and 573 K to the Celsius scale?
Subtract 273.15 from each kelvin value. 300 K − 273.15 = 26.85 °C, which is a warm room temperature, and 573 K − 273.15 = 299.85 °C, about the temperature of a very hot oven. Many textbooks round 273.15 to 273, giving 27 °C and 300 °C; use 273.15 for exact work.
Q7. How do you convert Fahrenheit to Kelvin?
Convert to Celsius first, then add 273.15: K = (°F − 32) × 5/9 + 273.15. For 68 °F: (68 − 32) × 5/9 = 20 °C, and 20 + 273.15 = 293.15 K. You can also go through Rankine: add 459.67 to get °R, then multiply by 5/9, which gives the same 293.15 K.
Q8. At what temperature are Celsius and Fahrenheit the same?
They are equal at −40. Setting C equal to C × 9/5 + 32 and solving gives C = −40, so −40 °C is exactly −40 °F. Above −40 the Fahrenheit number is always the larger one, and below it the Celsius number is larger. No other temperature reads the same on both scales.
Q9. Is 98.6 °F really normal body temperature?
It is the Fahrenheit equivalent of 37 °C, an average reported by Wunderlich in the 1860s, but it is not a fixed normal. Modern studies put the average oral temperature nearer 36.6 °C, or 97.9 °F, with a normal range of roughly 36.1 to 37.2 °C. Temperatures also vary by time of day, age and where they are measured.
Q10. How do you convert an armpit temperature to an oral temperature?
Add about 0.3 to 0.6 °C, or 0.5 to 1 °F, to the armpit reading. An armpit reading of 37.4 °C is roughly 37.7 to 38.0 °C by mouth. Ear and rectal readings are usually 0.3 to 0.6 °C higher than oral. These are averages; thermometers and people vary, so always record where the temperature was taken.
Q11. What is 350 °F in Celsius for an oven?
350 °F is (350 − 32) × 5/9 = 176.7 °C, which recipes round to 180 °C. It matches gas mark 4. In a fan or convection oven, set about 20 °C lower, so roughly 160 °C, because moving air cooks faster. Oven dials are often 10 to 20 °C out, so an oven thermometer is worth having.
Q12. How do you convert gas mark to Celsius and Fahrenheit?
Above gas mark 1, each mark adds about 25 °F, so °F ≈ 250 + 25 × mark. Gas mark 4 is 350 °F, or 180 °C; gas mark 6 is 400 °F, or 200 °C; gas mark 8 is 450 °F, or 230 °C. Below mark 1, the half and quarter marks are about 250 °F and 225 °F.
Q13. How do you convert a temperature difference?
Multiply by the ratio of degree sizes and leave out the offset. A rise of 10 °C is a rise of 18 °F, not 50 °F, and a rise of 10 K. The same rule applies to a thermometer tolerance: ± 0.5 °C is ± 0.9 °F. Choose Difference in the calculator to convert changes and ranges correctly.
Q14. Why is Kelvin written without a degree sign?
Since 1967 the kelvin has been an SI unit in its own right, like the meter or the second, rather than a degree on a scale. So you write 300 K and say three hundred kelvin. Celsius and Fahrenheit keep the degree sign: 26.85 °C and 80.33 °F. A space always separates the number from the unit.
Q15. What is the Rankine scale?
Rankine is an absolute scale that uses Fahrenheit-sized degrees. Zero is absolute zero, and °R = °F + 459.67, or K × 9/5. Water freezes at 491.67 °R and boils at 671.67 °R. It is mainly used in US engineering thermodynamics, where absolute temperatures are needed but the rest of the work is in US customary units.
Q16. Why do you add 273.15 to convert to Kelvin?
Absolute zero, the lowest possible temperature, is −273.15 °C. Kelvin starts counting from there with the same size of degree as Celsius, so 0 °C sits 273.15 kelvin above absolute zero. Since 2019 the kelvin is defined by fixing the Boltzmann constant, and the offset of 273.15 between the two scales is exact.
Q17. How do you convert temperature in Excel?
Use the CONVERT function: =CONVERT(A2,"C","F") turns Celsius in A2 into Fahrenheit, and =CONVERT(A2,"F","C") goes back. Kelvin is "K" and Rankine is "Rank". Or type the formula directly, =A2*9/5+32. The unit codes are case sensitive, so "c" instead of "C" returns an #N/A error. Fill the formula down a column to convert a whole list of readings at once.
Q18. How do you convert temperature in Python or R?
In Python, f = c * 9 / 5 + 32 and c = (f - 32) * 5 / 9; round the result to remove binary noise such as 37.00000000000001. R uses the same expressions and works on whole vectors at once. The scripts in Sections 10 and 11 convert every scale, check for absolute zero and print a chart.
Q19. What is room temperature in Celsius and Fahrenheit?
Room temperature is usually taken as 20 to 25 °C, which is 68 to 77 °F. Science often uses 25 °C, or 298.15 K, as standard ambient temperature, and 20 °C for laboratory glassware calibration. Comfortable indoor temperatures are often 20 to 22 °C, or about 68 to 72 °F, in heated buildings.
Q20. How do you make a Fahrenheit to Celsius conversion chart?
Choose a range and a step, then apply °C = (°F − 32) × 5/9 to each row. From 0 to 220 °F in steps of 10 gives 23 rows, from −17.8 °C to 104.4 °C. Each 10 °F step adds 5.56 °C. The chart mode in Section 2 builds the table for any range and exports it as a PDF.
📑 20. Cite This Tool
StatsUnlock. (2026). Temperature converter [Interactive laboratory tool]. https://statsunlock.com/temperature-converter/@misc{statsunlock_temperature_converter_2026, title={Temperature Converter}, author={{StatsUnlock Team}}, year={2026}, note={Interactive laboratory tool}, url={https://statsunlock.com/temperature-converter/}}Temperatures were converted with the exact SI relations (°F = 1.8 °C + 32; K = °C + 273.15) using the StatsUnlock Temperature Converter (2026).🔗 21. Related Tools
Density and SG at any reference temperature, 0 to 40 °C.
Write 1.380649 × 10⁻²³ J/K and other constants.
Make solutions at the right concentration.
Average repeated thermometer readings.
Spread of repeated temperature readings.
An interval for a mean temperature.
Calibrate a thermometer against a reference.
Summaries of a temperature log in one table.
Use these to summarize repeated temperature readings and to work with temperature-dependent lab quantities.
📖 22. Glossary of Terms
| Term | Plain-English meaning |
|---|---|
| Absolute zero | The lowest possible temperature: 0 K = −273.15 °C = −459.67 °F. |
| Axillary | Measured in the armpit. |
| Boltzmann constant | k = 1.380649 × 10⁻²³ J/K exactly; defines the kelvin since 2019. |
| Celsius (°C) | Scale with water freezing at 0 and boiling at 100 (1 atm). |
| Convection (fan) oven | Oven with a fan; needs about 20 °C less. |
| Crossover | −40, where °C and °F are equal. |
| Delisle (°De) | Reversed historical scale: water boils at 0. |
| Fahrenheit (°F) | Scale with water freezing at 32 and boiling at 212. |
| Fixed point | A reproducible temperature used to calibrate thermometers. |
| Gas mark | UK oven setting; mark 4 ≈ 180 °C. |
| Ice point | 0 °C, ice and water together at 1 atm. |
| ITS-90 | International Temperature Scale of 1990. |
| Kelvin (K) | SI unit of temperature; no degree sign. |
| Rankine (°R) | Absolute scale with Fahrenheit-sized degrees. |
| Réaumur (°Ré) | Historical scale: water boils at 80. |
| Rømer (°Rø) | Historical scale: water freezes at 7.5, boils at 60. |
| Temperature difference | A change or range; converts without the offset. |
| Triple point of water | 273.16 K (0.01 °C), where ice, water and vapor coexist. |
| Tympanic | Measured in the ear. |
| Temporal | Measured across the forehead. |
📚 23. References
Peer-reviewed sources behind this temperature converter: the International Temperature Scale of 1990, the 2019 redefinition of the kelvin and the Boltzmann constant, thermometry, body temperature by measurement site, fever thresholds and normal ranges, and uncertainty. Standards (SI Brochure 9th edition, ITS-90, ISO 80000-5) are named where they are used. Every DOI checked October 2026.
- Bijur, P. E., Shah, P. D., & Esses, D. (2016). Temperature measurement in the adult emergency department: Oral, tympanic membrane and temporal artery temperatures versus rectal temperature. Emergency Medicine Journal, 33(12), 843–847. https://doi.org/10.1136/emermed-2015-205122
- Cole, T. J. (2015). Too many digits: The presentation of numerical data. Archives of Disease in Childhood, 100(7), 608–609. https://doi.org/10.1136/archdischild-2014-307149
- Craig, J. V., Lancaster, G. A., Taylor, S., Williamson, P. R., & Smyth, R. L. (2002). Infrared ear thermometry compared with rectal thermometry in children: A systematic review. The Lancet, 360(9333), 603–609. https://doi.org/10.1016/S0140-6736(02)09783-0
- Fischer, J., Fellmuth, B., Gaiser, C., Zandt, T., Pitre, L., Sparasci, F., Plimmer, M. D., de Podesta, M., Underwood, R., Sutton, G., Machin, G., Gavioso, R. M., Madonna Ripa, D., Steur, P. P. M., Qu, J., Feng, X. J., Zhang, J., Moldover, M. R., Benz, S. P., White, D. R., Gianfrani, L., Castrillo, A., Moretti, L., Darquié, B., Moufarej, E., Daussy, C., Briaudeau, S., Kozlova, O., Risegari, L., Segovia, J. J., Martín, M. C., & del Campo, D. (2018). The Boltzmann project. Metrologia, 55(2), R1–R20. https://doi.org/10.1088/1681-7575/aaa790
- Geneva, I. I., Cuzzo, B., Fazili, T., & Javaid, W. (2019). Normal body temperature: A systematic review. Open Forum Infectious Diseases, 6(4), ofz032. https://doi.org/10.1093/ofid/ofz032
- Goldberg, D. (1991). What every computer scientist should know about floating-point arithmetic. ACM Computing Surveys, 23(1), 5–48. https://doi.org/10.1145/103162.103163
- Kragten, J. (1994). Calculating standard deviations and confidence intervals with a universally applicable spreadsheet technique. Analyst, 119(10), 2161–2165. https://doi.org/10.1039/AN9941902161
- Machin, G. (2018). The kelvin redefined. Measurement Science and Technology, 29(2), 022001. https://doi.org/10.1088/1361-6501/aa9ddb
- Mackowiak, P. A., Wasserman, S. S., & Levine, M. M. (1992). A critical appraisal of 98.6 °F, the upper limit of the normal body temperature, and other legacies of Carl Reinhold August Wunderlich. JAMA, 268(12), 1578–1580. https://doi.org/10.1001/jama.1992.03490120092034
- Mogensen, C. B., Wittenhoff, L., Fruerhøj, G., & Hansen, S. (2018). Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes. BMC Pediatrics, 18(1), 15. https://doi.org/10.1186/s12887-018-0994-1
- Moldover, M. R., Tew, W. L., & Yoon, H. W. (2016). Advances in thermometry. Nature Physics, 12(1), 7–11. https://doi.org/10.1038/nphys3618
- Newell, D. B., Cabiati, F., Fischer, J., Fujii, K., Karshenboim, S. G., Margolis, H. S., de Mirandés, E., Mohr, P. J., Nez, F., Pachucki, K., Quinn, T. J., Taylor, B. N., Wang, M., Wood, B. M., & Zhang, Z. (2018). The CODATA 2017 values of h, e, k, and NA for the revision of the SI. Metrologia, 55(1), L13–L16. https://doi.org/10.1088/1681-7575/aa950a
- Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015). Accuracy of peripheral thermometers for estimating temperature: A systematic review and meta-analysis. Annals of Internal Medicine, 163(10), 768–777. https://doi.org/10.7326/M15-1150
- Obermeyer, Z., Samra, J. K., & Mullainathan, S. (2017). Individual differences in normal body temperature: Longitudinal big data analysis of patient records. BMJ, 359, j5468. https://doi.org/10.1136/bmj.j5468
- Preston-Thomas, H. (1990). The International Temperature Scale of 1990 (ITS-90). Metrologia, 27(1), 3–10. https://doi.org/10.1088/0026-1394/27/1/002
- Protsiv, M., Ley, C., Lankester, J., Hastie, T., & Parsonnet, J. (2020). Decreasing human body temperature in the United States since the Industrial Revolution. eLife, 9, e49555. https://doi.org/10.7554/eLife.49555
- Ring, E. F. J., & Ammer, K. (2012). Infrared thermal imaging in medicine. Physiological Measurement, 33(3), R33–R46. https://doi.org/10.1088/0967-3334/33/3/R33
- Stöck, M., Davis, R., de Mirandés, E., & Milton, M. J. T. (2019). The revision of the SI: The result of three decades of progress in metrology. Metrologia, 56(2), 022001. https://doi.org/10.1088/1681-7575/ab0013
- Sund-Levander, M., Forsberg, C., & Wahren, L. K. (2002). Normal oral, rectal, tympanic and axillary body temperature in adult men and women: A systematic literature review. Scandinavian Journal of Caring Sciences, 16(2), 122–128. https://doi.org/10.1046/j.1471-6712.2002.00069.x
- Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021). CODATA recommended values of the fundamental physical constants: 2018. Reviews of Modern Physics, 93(2), 025010. https://doi.org/10.1103/RevModPhys.93.025010